Why is liquid carrying over past my demister pad?
The symptom
Liquid droplets reach equipment downstream of the demister. Possible effects include fouled compressor blades, off-spec overhead product and pipe corrosion. Carry-over can occur even when the pad appears intact at inspection.
Root causes
- 01 Gas velocity outside the design range can reduce separation. High velocity re-entrains captured liquid. At low velocity, fine droplets can follow the gas around the wires.
- 02 Gaps between pad segments or at the vessel wall allow gas to bypass the pad. Even a small bypass can reduce separation.
- 03 Pad density or thickness may not suit the droplet distribution. A pad for coarse mist can pass fine droplets after an upstream process change.
- 04 Polymer, salts or coke can block the wire structure. Local gas velocity rises and liquid may be re-entrained.
Suitable filter media
- Review the pad against current operating data. Density, thickness and free area must suit gas rate and droplet size.
- Limit bypass with suitable support grids, segment overlap and wall sealing.
- For fine mist, assess a higher pad density or a co-knit layer of wire and yarn matched to the fine-droplet fraction.
- For fouling service, consider a more open, thicker pad and provide cleaning access in the design.
Effect on downtime
Carry-over can damage downstream equipment and produce off-spec material. Repair costs and downtime depend partly on that equipment. Review demister separation and installation before limiting repairs to the downstream damage.
Prevention
- Record gas rate at every process change and check that it remains within the design range.
- Inspect segment joints and wall clearances whenever the vessel is entered.
- Specify the replacement as an assembly of pad, grid and sealing so the components fit the installation together.